STEP I
MOUNTING PREPARATION
CAUTION: FIXTURE WEIGHTS ABOUT 30 POUNDS
Using template (A) lay over junction box (B) on the wall.
Mark at (3) hole. (See Fig.1)
Drill wall for the hardware appropriate for the type wall.
Use 1/4 diameter bolt.
Pull the supply wires (C) from junction box (B) .
STEP II
FIXTURE MOUNTING PREPARATION
(See Fig. 2)
To open door (E), loosen (2) retaining screws (F).
For optional quick release door latch, push pin (D) to open
door (E).
Loosen (4) screws (X) and them remove reflector (H).
Loosen screws (O), remove cover (P) and discard.
STEP III
FIXTURE MOUNTING
(See Fig.3)
Insert all wires (C) through slit on gasket opening at the
back of housing.
Hang fixture on the mounting hardware at the wall through
key-slots opening (J).
Tighten bolts (K) securely.
Apply caulking sealant around the top and two sides of the
housing.
Step IV
WIRING
(See Fig. 3)
POWER MUST BE OFF.
(WIRING MUST BE PERFORMED BY
A QUALIFIED ELECTRICIAN)
Wire service leads to fixture power leads according to local
and National Electric Codes.
For direct wire connections, connect ground wire to green
wire then push ware back to J-box on the wall. Connect
black to black and white to neutral then push connections
back inside J-box (B).
When supplied with optional terminal block (L) or fuseblock
(M) connect service leads to these devices.
FOR THROUGH WIRING USING CONDUIT
Remove hole plug (N) for the conduit entry
Use pipe sealant before engaging conduit fittings to prevent
water leakage.
Loosen screw (O) and remove wire cover (P).
Insert fixture lead wires (Q) through grommet ( R ).
Make the wire connections.
Replace cover (P) making sure not to pinch wires.
INSTALLATION INSTRUCTIONS FOR WALLPACK LUMINAIRE
Outdoor Lighting
laredo
WARNING: DISCONNECT POWER BEFORE INSTALLATION OR MAINTENANCE.
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL
LUMINAIRE, FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - FIXTURE MOUNTING

STEP I MOUNTING PREPARATIONCAUTION: FIXTURE WEIGHTS ABOUT 30 POUNDS• Using template (A) lay over junction box (B) on the wall.Mark at (3) hole. (See

Seite 2 - INSTALLING VANDAL SHIELD

STEP V LAMPING• Make sure that the lamp size and type matches the ballastspecifications.• Replace reflector (H).• Engage the lamp to socket (S).• For

Kommentare zu diesen Handbüchern

Keine Kommentare